Repair Flat Roof



| Backwater Laps | Boot Not Lapped/Sealed Correctly | Counter Flashing Loose |
| Ell Flashing Behind Wall Surface | Ell Flashing Not Sealed Properly | Ell Flashing Uplifting |
| Fair/Unfair Metals Touching | Fasteners Uplifting | Fiberglass Intermat Showing |
| Flashing Rusting | Flashing Seams Separating | Flat Tie-In not Sealed Properly |
| Gable End Flashing Not Correct | Granules Loss | Improper Fastener Installation |
| Improper Fastener Type | Improper Number of Fasteners | No Ell Flashing Installed |
| No Sealant at Flashings | No Starter Strip | No Wall Cap/Coupling |
| Offset Not Correct | Pan Roof Tie-In Not Correct | Pitch Transition not Flashed |
| Plastic Boots | Ponding Water | Roof Recovered Offset Not Correct |
| Slipping: Delaminating / Sliding | SPF: Improper Number of Fasteners | SPF: Torn/Cracked/Broken Surface |
| Tar: Fiberglass Intermat Showing | Tar:Torn/Cracked/Broken Surface | Torn/Cracked/Broken Surface |
| Valley Metal Buckling | Vent Not Lapped/Sealed Correctly |
Repair Shingle Roof



| Aluminum Ridge Vent w/Nails | Backwater Lap | Blown Off Cap |
| Boot Lapped / Sealed Correctly | Counter Flashing Loose | Drip Edge with Flat Shelf |
| Ell Flashing Behind Wall Surface | Ell Flashing Not Sealed Properly | Ell Flashing Uplifting |
| Fair/Unfair Metals Touching | Fasteners In The Valley | Fasteners Uplifting |
| Fiberglass Intermat Showing | Flashing Rusting | Flashing Seams Separating |
| Flat Tie-In not Sealed Properly | Gable End Flashing | Granules Loss |
| Improper Fastener Installation | Improper Fastener Type | Improper Number of Fasteners |
| Inspection: Flashings | No Ell Flashing Installed | No Sealant at Flashings |
| No Starter Strip | No Wall Cap / Coupling | Off Ridge Vents not Angled |
| Offset Not Correct | Pan Roof Tie-In Not Correct | Pitch Transition not Flashed |
| Plastic Boots Used | Punctures in Roof | Roof Recovered |
| Shingle “W” Valley | Shingles Curling | Slipping: Delaminating / Sliding |
| Torn/Cracked/Broken Surface | Turbine Vents Not Working | Valley Metal Buckling |
| Vent Not Lapped/Sealed |
Repair Tile Roof



| Backwater Laps | Battens Causing Water Backup | Blown Off Cap |
| Boot Lapped/Sealed Correctly | Chipped Tile Corners | Concrete Eve Riser |
| Counter Flashing Loose | Double #30lb Underlayment | Drip Edge With Flat Shelf |
| Duro-Loc Installed | Ell Flashing Behind Wall Surfaces | Ell Flashing Not Sealed Properly |
| Ell Flashing Uplifting | Fair/Unfair Metals Touching | Fasteners In The Valley |
| Fasteners Uplifting | Flashing Rusting | Flashing Seams Separating |
| Flat Tie-In Not Sealed Properly | Gable End Flashing | Improper Fastener Installation |
| Improper Fastener Type | Improper Number Of Fasteners | Lead Flashings On A Tile Roof |
| No Ell Flashing Installed | No Eve Riser Installed | No Ridge Anchor Installed |
| No Sealant At Flashings | No Wall Cap/Coupling | Not All Tiles Are Fastened |
| Off Ridge Vents Not Angled | Offset Not Correct | Pan Roof Tie-In Not Correct |
| Pitch Transition Not Flashed | Plastic Boots Used | Rake Tiles Held With Fasteners |
| Slipping: Delaminating / Sliding | Tile Cap In Valley | Tile Mortar Cap Loose |
| Tile Roof Cemented | Tiles Sliding Off Roof | Torn/Cracked/Broken Surface |
| Valley Metal Buckling | Vent Not Lapped/Sealed Correctly |
Repair Metal Roof



| Backwater Laps | Boot Lapped/Sealed Correctly | Counter Flashing Loose |
| Drip Edge With Flat Shelf | Ell Flashing Behind Wall Surfaces | Ell Flashing Not Sealed Properly |
| Ell Flashing Uplifting | Fair/Unfair Metals Touching | Fasteners In The Valley |
| Fasteners Uplifting | Flashing Rusting | Flashing Seams Separating |
| Flat Tie-In Not Sealed Properly | Gable End Flashing | Improper Fastener Installation |
| Improper Fastener Type | Improper Number Of Fasteners | No Ell Flashing Installed |
| No Sealant At Flashings | No Wall Cap/Coupling | Off Ridge Vents Not Angled |
| Offset Not Correct | Pan Roof Tie-In Not Correct | Pitch Transition Not Flashed |
| Plastic Boots Used | Repair Metal | Roof Recovered |
| Slipping: Delaminating / Sliding | Torn/Cracked/Broken Surface | Valley Metal Buckling |
| Vent Not Lapped/Sealed Correctly |